Features and Benefits
- Provide analog output for WTS acquisition modules
- One to one transmission up to 2000 updates per second (dependent on acquisition module)
- Industrial & desktop versions available
WTS-BS-5 Wireless Analog Output Receiver Module
The pricing listed on our website is only for U.S. buyers and all pricing is subject to change without notice. Any inquiries for products from buyers outside of the U.S. will receive a quote and availability from the licensed distributor nearest your region. These prices will be based on product availability, currency conversions, markets, taxes, shipping costs, as well as local support.
The WTS-BS-5 Wireless Analog Output Receiver converts data from a WTS wireless transmitter module into an analogue output and forms part of the WTS modular telemetry system. Data from any of the WTS range of transmitters can be used.
The data sent by transmitter modules can be utilized by multiple receivers such as displays, handheld readers, analog outputs, relay modules and computer interfaces. Receivers support common industrial power supplies and are available in robust IP rated enclosures with internal antennas optimized to give outstanding coverage.
The WTS-BS-5 offers, as standard, a user choice of analog outputs; 0-10 V, 4-20 mA, 0-20 mA, ±10 V, ±5 V. A choice of a desktop enclosure or an IP67 sealed enclosure allows selection of a module to suit your individual application. The WTS Toolkit offers a fast and simple way to configure the analog output scaled from any engineering unit input.
The WTS-BS-5 Wireless Analog Output Receiver converts data from a WTS wireless transmitter module into an analogue output and forms part of the WTS modular telemetry system. Data from any of the WTS range of transmitters can be used.
The data sent by transmitter modules can be utilized by multiple receivers such as displays, handheld readers, analog outputs, relay modules and computer interfaces. Receivers support common industrial power supplies and are available in robust IP rated enclosures with internal antennas optimized to give outstanding coverage.
The WTS-BS-5 offers, as standard, a user choice of analog outputs; 0-10 V, 4-20 mA, 0-20 mA, ±10 V, ±5 V. A choice of a desktop enclosure or an IP67 sealed enclosure allows selection of a module to suit your individual application. The WTS Toolkit offers a fast and simple way to configure the analog output scaled from any engineering unit input.
U.S. dimensions and capacities are provided for conversion only. Standard products have International System of Units (SI) capacities and dimensions.
U.S. dimensions and capacities are provided for conversion only. Standard products have International System of Units (SI) capacities and dimensions.
You will need to connect a power supply to the WTS-BS-5-DT for it to operate and to enable configuration using a base station and the T24 Toolkit software.
Power is supplied via the screw terminals and can be in the range of 9 Vdc to 36 Vdc.
Depending on the analogue output module you have you will need to refer to one of the two
following diagrams:
To configure the required output range the DIP switches (SW2) require setting as follows. To access the DIP switches you will need to remove the cover from the case.
| SW2 Switch Settings | ||||||||
| Range | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| 0-10 V | On | Off | Off | X | X | Off | On | Off |
| +/-10 V | Off | Off | On | X | X | Off | On | On |
| 0-5 V | On | On | Off | X | X | Off | Off | Off |
| +/-5 V | Off | Off | On | X | X | Off | Off | On |
| 0-20 mA Sink | X | X | X | Off | On | On | Off | Off |
| 0-20 mA Source | X | X | X | On | Off | On | On | Off |
| 4-20 mA Sink | X | X | X | Off | On | On | Off | On |
| 4-20 mA Source | X | X | X | On | Off | On | On | On |
Where X = Doesn’t matter
| LED | Description |
| Mode | Flashing at 2Hz indicates normal operation. Constantly on indicates currently attempting to pair. Flashing at 4Hz indicates a failed pair attempt. |
| Activity | LED lights for 20ms each time data arrives. When data arrives at a rate greater that 50Hz the LED will appear constantly illuminated. |
| Timeout | Lost communications with the remote module. |
| Error | Remote module is reporting an error. |
| Battery Low | Remote module is reporting a low battery. |
For more information visit Electrical Wiring Diagrams
| Dimensions | 3.30 × 6.50 × 2.20 in |
|---|
U.S. dimensions and capacities are provided for conversion only. Standard products have International System of Units (SI) capacities and dimensions.
U.S. dimensions and capacities are provided for conversion only. Standard products have International System of Units (SI) capacities and dimensions.
You will need to connect a power supply to the WTS-BS-5-DT for it to operate and to enable configuration using a base station and the T24 Toolkit software.
Power is supplied via the screw terminals and can be in the range of 9 Vdc to 36 Vdc.
Depending on the analogue output module you have you will need to refer to one of the two
following diagrams:
To configure the required output range the DIP switches (SW2) require setting as follows. To access the DIP switches you will need to remove the cover from the case.
| SW2 Switch Settings | ||||||||
| Range | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| 0-10 V | On | Off | Off | X | X | Off | On | Off |
| +/-10 V | Off | Off | On | X | X | Off | On | On |
| 0-5 V | On | On | Off | X | X | Off | Off | Off |
| +/-5 V | Off | Off | On | X | X | Off | Off | On |
| 0-20 mA Sink | X | X | X | Off | On | On | Off | Off |
| 0-20 mA Source | X | X | X | On | Off | On | On | Off |
| 4-20 mA Sink | X | X | X | Off | On | On | Off | On |
| 4-20 mA Source | X | X | X | On | Off | On | On | On |
Where X = Doesn’t matter
| LED | Description |
| Mode | Flashing at 2Hz indicates normal operation. Constantly on indicates currently attempting to pair. Flashing at 4Hz indicates a failed pair attempt. |
| Activity | LED lights for 20ms each time data arrives. When data arrives at a rate greater that 50Hz the LED will appear constantly illuminated. |
| Timeout | Lost communications with the remote module. |
| Error | Remote module is reporting an error. |
| Battery Low | Remote module is reporting a low battery. |
For more information visit Electrical Wiring Diagrams
| Dimensions | 3.30 × 6.50 × 2.20 in |
|---|